Marmitek SWM1P Operations Instructions

Browse online or download Operations Instructions for Network switches Marmitek SWM1P. Marmitek SWM1P Operating instructions User Manual

  • Download
  • Add to my manuals
  • Print

Summary of Contents

Page 1 - Type PMIX35

Marmitek X-10Programming and Measuring InterfaceType PMIX35

Page 2 - Introduction

101 Programming and measuring functions1.2.1 Measuring signal levelsThe measuring of signal levels in Marmitek X-10 installations allows the rapid det

Page 3 - Software installation

0 2 V 4 V Max111 Programming and measuring functionsFigure 7: Setting the transmission level.Figure 9: Network diagnostics data.1.2.1.2 Sensitivity of

Page 4

121 Programming and measuring functionsThe table below gives an overview of the various counters and their functions. All counters can be set to 0 wit

Page 5 - 1.1 Programmer

131 Programming and measuring functionsExample:Follow the steps below to automatically send two command lines to the address "A01".1. Follow

Page 6

141 Programming and measuring functionsErrors in the log screen are indicated with red shading. The table below gives several examples of suspect mess

Page 7 - 6. Click:

151 Programming and measuring functions1.3 Network validationIn this tab page, a quick and simple network analysis can be performed before the deliver

Page 8 - 1. Click:

161 Programming and measuring functions1.3.2 Interpreting the network validation dataThe PMIX35 software will display the transmission, reception, noi

Page 9 - 1.2 Analyzer

172 The PMIX35 as data interfaceThe PMIX35 supports the CTX15/35 protocol as standards and, in addition, has a number of extra functions. This means t

Page 10 - 1.2.1 Measuring signal levels

182 The PMIX35 as data interface2.2 Protocol description2.2.1 COM port settingsSee the figure below for the required COM port settings:2.2.2 COM port

Page 11 - 1.2.2 Network diagnostics

192 The PMIX35 as data interface2.2.3 Communication formatAll communication is ASCII format. The messages between the PC application and the PMIX35 ar

Page 12 - Example:

2Functions• Sending and receiving commands. • Measuring the signal level and noise level of incomingmessages.• Measuring network impedance.• Sending m

Page 13 - 1.2.3.4 Receiving messages

202 The PMIX35 as data interfaceTransmitter Format DescriptionPC SP{D} Send Position: The position of the transmitted data on the mains voltage with r

Page 14 - Sample log file: pmix35.log

212 The PMIX35 as data interfaceTransmitter Format DescriptionPC RQ Data Request: After the connection has been established, a Data Request is made to

Page 15 - 1.3 Network validation

222 The PMIX35 as data interfaceTransmitter Format DescriptionPC LW{LLL..L} Line Write: With this message, the PC application commands the PMIX35 to t

Page 16

232 The PMIX35 as data interfaceHex Code Hex Code Hex Code Hex Code Hex Code Hex Code20 (Space) 30 0 40 @ 50 P 60 ` 70 p21 ! 31 1 41 A 51 Q 61 a 71 q2

Page 17

Marmitek X-10 home automationRated voltage 230 Vac, 50 HzTotal power consumption Max. 2.5 WSignal transmission Adjustable from 0 to 5 Vpp (per 25 mV

Page 18 - 2.2 Protocol description

CopyrightsMarmitek is a trademark of Pattitude B.V., PMIX35™ is a trademark of Marmitek B.V. All rights reserved. Copyright and all other proprietary

Page 19 - 2.2.3 Communication format

3Software installationFollow the steps below to install the PMIX35 software.Please note: Follow the installation procedure below before connecting the

Page 20 - 2.2.4 Types of messages

4After starting up, the PMIX35 software will automatically search for the presence of a connected PMIX35 and attempt toestablish a connection. The sof

Page 21

5The PMIX35 software can be used for:• Programming Marmitek X-10 modules.• Measuring and testing an installation. For this purpose the PMIX35 software

Page 22

61 Programming and measuring functions1.1.1 Programming standard modulesStandard modules (without PRG function, see table 1-2) can be easily programme

Page 23 - Character: $>9000RQ

71 Programming and measuring functionsPPROG.NLSAIX12PROG.5. Switch the module to programming mode by pressing the programming button for 3 seconds.6.

Page 24 - 2.3 Technical data

81 Programming and measuring functions1.1.2 Programming using automatic programming modeThe latest generation of Marmitek X-10 modules can be (re)prog

Page 25 - 20317 - 20100928

91 Programming and measuring functions3. Within 5 seconds, activate the programming mode of the module according to the table below: 1.2 AnalyzerThe