3 © MARMITEK
Figure 2.4: Opening the Housing
Housing
Screw
Switching off the siren
1. Press 9 followed by 1111.
2. Now enter 9155 (the display shows: 5.WIRED SIREN ENABLED).
3. Now press (the display shows: 5.WIRED SIREN DISABLED).
4. Press 9 for confirmation.
5. Press 8 4 times to leave the installation menu.
INSTALLATION
1. Disconnect the AC power from the ProGuard800 control panel.
2. Remove the housing screw located at the bottom of the front cover.
3. Using a screwdriver carefully press the release tabs as shown in Figure 2.4.
4. Lift the front cover away from the back of the housing. You will notice that the
front cover is attached to the back with two fastening bands and the keypad’s
flat cable.
5. Disconnect the backup battery pack connector to the Control Panel.
6. Slide the GSM800 PCB at it’s place by first putting the right side of the pcb in
place and then clicking the left side in it’s holder. Make sure connectors are at
the bottom of the PCB.
7. Connect the small flat cable between the GSM800 PCB (5) and the Control
Panel (Main Board) PCB.
8. Put the plug in the socket.
9. Follow these steps in the ProGuard800 Installation manual:
12.5: Find Modules
10.7.2: PIN Code
10.7.3: SMS Center
10. Place the SIM card in the SIM card holder.