7
MULTIPLEXER SYSTEM OPERATION
5. REC TYPE SET
- Allows setting of the recording mode of TIME LAPSE VCR to be
connected with MULTIPLEXER.
• Set the cursor on the 5.REC TYPE SET using
and keys,
and press ENTER key to enter the SUB MENU on the right.
• To record intermittently, locate the cursor on the 1. TIMELAPSE using
and keys, and press ENTER key.
To record in 60 fields/sec (NTSC standard) or 50 fields/sec
(PAL standard), select 2. REAL TIME and press ENTER key.
• In case of TIME LAPSE record mode, connect SW TRIGGER signal
from VCR to the TERMINAL SW IN of main unit, connect GND signal to
COM, and connect SW-OUT signal to VTI.
If the connection is not properly established, only the signal from a
certain camera is not recorded.
If the VCR’s record time setting is something other than the TIME
LAPSE mode, signals from 4 cameras may not be recorded properly.
• In case of REAL TIME record mode, camera signal output is
automatically switched by fields regardless of the SW TRIGGER signal
from the VCR.
• In case of TIME LAPSE record mode, camera signal output is
automatially switched by field or frame of the SW TRIGGER signal from
the TIME LAPSE VCR.
• Switch out timing of TIME LAPSE VCR must be selected frame.
If switch out timing of TIME LAPSE VCR is selected field, the recording
image missed some fields.
• Press the S MENU key to return to the MAIN MENU.
6. ALARM/LOSS SET
- ALARM / LOSS BUZZER SET-UP
1. ALARM : Set BUZZER ON/OFF when ALARM occurs.
2. LOSS : Set BUZZER ON/OFF when LOSS occurs.
3. HOLD TIME: Time to continue ALARM state after ALARM occurs.
• From the <MENU>, set the cursor on the 6. ALARM/LOSS SET using
and
keys, and press ENTER. [ALARM/LOSS SET] screen
appears. Set the cursor on the setting entry using
and
keys and
set or change the values in the entry using
and
keys.
• In [ALARM/LOSS SET] screen, configure 3. HOLD TIME to 5 seconds
interval for the first second to the first minute, and 1 minute interval for
the first minute to the 30th minute, as described above.