Marmitek SC9000 User's Guide Page 32

  • Download
  • Add to my manuals
  • Print
  • Page
    / 44
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 31
10.5 All Home Automation functions at a glance
Name Description Module set to address
Comfort lighting You can switch your lighting using the buttons Lights ON and
Lights OFF on your key chain remote control. A1 and A2
Exit delay Lights are switched on during the exit delay. A1 and A2
Alarm lighting In the case of an alarm, the lights will flash during 4 minutes and
then remain on. A1 and A2
Status indicator The lights are switched on when the system is set to ARM AWAY. B1
External Siren PH7208 Extra 110dB siren. A1 or A2
Extra universal siren Connect your own siren to a Marmitek AM12 or AD10 module. B2
Sensor trigger function In case of an alarm on zone 27 to 32 an ON or OFF command is sent B7 B8 B9 B10 B11 B12
This table uses the unchanged settings for the basic console address.
10.6 Basic address for Home Automations functions
The basic address is set to control multiple Home Automation modules on the SC9000. The standard basic address is A1. The A in
this address is called the HouseCode. The HouseCode of the console, the remote controls and the Home Automation modules all
have to have the same letter. The 1 in the basic address is called the UnitCode. If your neighbours also have a Marmitek security
system, it may be necessary to change the basic addresses and the addresses of your Marmitek X-10 modules.
If you change the HouseCode of the console, the addresses for the Home Automation functions also change. Example: You
change the HouseCode from A into C.
Name Description Module set to address
Comfort lighting Reacts to the Lights ON and Lights OFF button on your key chain
remote control. C1 and C2
Exit delay Lights are switched on during the exit delay. C1 and C2
Alarm lighting In the case of an alarm, the lights will flash during 4 minutes and
then remain on. C1 and C2
Status indicator The lights are switched on when the system is set to ARM AWAY. D1
External Siren PH7208 Extra 110dB siren. C1 or C2
Extra universal siren Connect your own siren to a Marmitek AM12 or AD10 module. D2
Sensor trigger function In case of an alarm on zone 27 to 32 an ON or OFF command is sent D7 D8 D9 D10 D11 D12
EXTRA OPTIONS
32 MARMITEK
20071_20090424_UG_SC9000_EN 30-07-2009 09:10 Pagina 32
Page view 31
1 2 ... 27 28 29 30 31 32 33 34 35 36 37 ... 43 44