Marmitek X-10 User Manual Page 12

  • Download
  • Add to my manuals
  • Print
  • Page
    / 40
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 11
© MARMITEK
12
3. Programming a function code
Determine the function of the module by sending the set-up command
belonging to the function twice via the power line (see following table).
The LED responds with a number of flashes according to the selected function
once two identical set-up commands have been received.
Function (sending) Setup command No. of LED flashes
3.1 On/Off switch commands
(switch or pushbutton switch)
ON 3x
3.2 Dimming commands via 1-
pole, normally open, contact
Momentary switch
BRIGHT 5x
3.3 Dimming commands via
momentary switch with two
normally open contacts
DIM 6x
3.4 Group commands All Lights ON 8x
The programming per function chapter explains how to program the above
functions with helpful examples.
4. Programming options
The TWM4 has the option of converting the internal status (from ON to OFF
or from OFF to ON) upon receiving a group command: All Lights On, All Lights
Off, All Units Off.
This option is only applicable with the following functions:
A. Sending On/Off switch commands with switch or with 1-pole, normally
open contact, Momentary switch.
B. Sending dimming commands with 1-pole, normally open contact,
Momentary switch.
The application of this option depends on how the TWM4 is used. If
the TWM4 controls a switch actuator that responds to a group
command, the options of the TWM4 will also have to respond to the
same group commands. As a result, the status of the interface (TWM4)
will always be synch with the switch actuator.